System Sensor RTS2 Multi-Signaling Accessory

System Sensor RTS2 Multi-Signaling Accessory
Images for general purposes only. Actual may be different than depicted.
System Sensor RTS2 Multi-Signaling Accessory

System Sensor RTS2 Multi-Signaling Accessory

SKU: RTS2
Rating:
Quantity Price Stock
43
Usually Ships 1-2 Weeks
$123.22     /ea
43
0
$0.00
0
$0.00
0
RTS2
System Sensor RTS2 Multi-Signaling Accessory

The National Fire Protection Association (NFPA) has published codes, standards, and recommended practices for the installation and use of this product. It is recommended that the installer be familiar with theses requirements, with local codes, and any special requirements of the local authority having jurisdiction. For further information, consult NFPA 72 and 90A requirements.

The System Sensor RTS2 and RTS2-AOS multi-signaling accessories are designed for use with System Sensor InnovairFlex 4-wire conventional duct smoke detectors only. The accessory has two bicolored LEDs that indicate the sensor status of up to two connected duct smoke detectors. The key switch on the unit can be used to select a connected duct detector sensor (either sensor 1 or sensor 2), and the selected sensor can be tested or both sensors can be reset simultaneously using the test/reset button. LED status indications
include: Standby (green blink), Trouble (amber), Maintenance (amber blink) and Alarm (red).

With the key switch selected, there is also the capability of obtaining a sensitivity measurement of the selected sensor using the SENS-RDR sensitivity reader (sold separately).

Specific Features of the RTS2 and RTS2-AOS include:
• Standby (Green Blink), Trouble (Amber), Maintenance (Amber Blink) and Alarm (Red) LEDs to indicate detector status
• Keyswitch to select desired sensor, enable test/reset button and sensitivity reading
• Test/reset button
• Sensitivity reading ability with SENS-RDR (sold separately)
• Selectable continuous or temporal tone
• AOS-Add-On-Strobe (included on RTS2-AOS model)
• Provisions for single- or double-gang box mounting
• Ability to discretely monitor two sensors when duct smoke detectors are configured in a 2-to-1 set up (See InnovairFlex duct smoke detector manual for reference.)
Operating Humidity Range 95% relative humidity; non-condensing
Operating Temperature Range 14°F to 140°F (-10°C to 60°C)
Sounder 85 dBA at ten feet
Voltage Range 20-29 VDC
Wire Connections Strip terminal, 14 AWG to 22 AWG wire

Q & A: Ask the Questions, share answers